Premium LCD Display Wall (46" & 55")

Download Product Brochure

24/7 Operational Guidlines

Super Narrow Bezels smoothly integrate into multi-screen applications creating virtually seamless images

Evolving large-screen imaging systems for today's visual information society. Mitsubishi Electric multi-screen displays contribute to ensuring the smooth flow of information in public spaces such as airports and train stations.

Specifications


Key Features

Digital Gradation Circuit

Our innovative digital gradation circuit provides uniform brightness distribution across the screen, resulting in the reproduction of sharp, vivid images from edge to edge on multi-screen configurations. This virtually eliminates the problem of decreased brightness at the edges of each screen.

without Digital Gradation Circuit with Digital Gradation Circuit

Colour Space Control

In addition to the Colour Calibration (Option), LM55P1 is equipped with an innovative digital colour space control circuit developed in-house for more precise colour and brightness adjustment as a LCD video wall. The circuit works to balance and blend colours, compensating for the colour and brightness discrepancies among panels. The ratios of each primary colour (Red/Green/Blue) and other colour mixtures are adjusted to provide consistent colour blending and superior uniformity on multi-screen configurations.

Full HD, LED-backlit LCD Panels with Super Narrow Bezel

Professional Premium grade LED-backlit panels with high brightness and contrast. The panels feature a super-narrow bezel width of 5.7mm that minimizes image content loss, a critical factor in multi-screen applications and also have Mitsubishi unique colour Patents that include Colour Space Control and Digital Gradiation Circuit.

Tiling Compatibility with Frame Compensation

Both models feature a frame compensation function that works in configurations of up to 25 panels (5 wide x 5 high). The ability to adjust panel bezel width enables extremely accurate image reproduction

 
frame compensation off frame compensation on
   
Optional Front-access Wall Mount Bracket (Option: BR-LM1KK)
When used in combination with our original wall mount kit, LCD panels can be accessed from the front-side of the system, facilitating simple servicing of panels either from the front or rear (possible in both landscape and portrait orientations).  
     
Colour Calibration for Multi-screen Applications (Option)

Utilising Mitsubishi Electric's original colour calibration software, the white point, brightness and gamma can be adjusted to ensure matching between adjacent panels.

without colour calibration with colour calibration
   
Equipped with Intel® OPS Slot

LM55P1 and LM46P1 are equipped with an Open Pluggable Specification (OPS) slot. Simply install the optional computer board* to expand the scope of applications. A variety of peripheral equipment can be connected quickly and easily.

  • * ARK-DS262GQ-U5A1E is product of Advantech, Co., Ltd.

 
Compatible with Crestron RoomView™ & AMX Device Discovery
Both the LM55P1 and, LM46P1 are compatible with both Crestron RoomView™ and AMX Device Discovery, widely used network management software. Control commands can be sent from a computer through the LAN network to enable setting changes and remote diagnosis of multiple displays for efficient centralised management.  
   
Enhanced Connectivity with Digital Terminals
A full range of digital input terminals are provided, including one HDMI, one DVI-D and one DisplayPort. In addition, the DVI-D output terminal makes, daisy chaining multiple monitors possible.

The following conditions apply for daisy chain connections:
1) Depending on cable length and signal source, up to four monitors can be connected when daisy chaining.
2) POWER SAVE should be set to OFF. Depending on computer compatibility, the POWER SAVE RGB setting may need to be set to OFF when using DisplayPort input.

Highly Reliable
Mitsubishi Electric’s super-narrow bezel product line utilises highly reliable commercial grade LCD panels and electrical components. Designed for durability and long-term use, they're ideal for applications such as flight information displays and digital signage boards.

Other Features
  • PIP, POP and Side-by-side
  • Digital Zoom
  • SDI Connection (Option)
  • Programmable Scheduling
  • Screen-saver
  • Power-on Delay
  • LAN Control
  • Display Port
  • Built-in Speakers
  • Remote Control (Option)
  • Closed Caption

Specifications: LM46P1-W

Model LM46P1
Dimensions (W x H x D) 1024 x 578.6 x 108mm (40.3 x 22.8 x 4.3")
Display device TFT LCD (SPVA)
Screen surface treatment Anti-glare (Haze 44%)
Mullion size (Total) B-to-B 5.7mm (Typ.) / A-to-A 5.9mm (Typ.)*1
Display resolution Full HD (1920 x 1080 Pixels)
Viewable image size 46" (H: 1024mm/V: 578.6mm)
Back light technology LED (Direct)
Viewing angle(H/V) 178 Degree (CR>10)
Display orientation Landscape / Portrait
Brightness 700cd/m2 (Typ., High Bright mode)
500cd/m2 (Typ., Standard mode)
Contrast ratio 3,500:1 (Typ.)
Display colours 16.7 million
Input connectors Video DVI-D (with HDCP) x 1, HDMI x 1, DisplayPort (1.1a) x 1, D-sub15 x 1, Composite (BNC Y: shared with component video) x 1, Component(YPbPr) <BNC> x 1
Audio PC-audio (mini-pin) x 1, RCA-audio x 1
Control RS-232C x 1, ø3.5mm stereo mini jack x 1, LAN control (RJ-45) x 1
Output connectors Video DVI-D (with HDCP)
Audio RCA pin-jack x 1, External speaker jack x 1
Control RS-232C x 1, ø3.5mm stereo mini jack x 1
Signal frequency Analog H: 15.625/15.734/31.5-91.1KHz, V: 50/58-85Hz, Pixel clock: 13.5-165MHz
Digital H: 31.5-91.1KHz, V: 58-85Hz, Pixel clock: 25-165MHz
Power consumption 160W (Typ., Hight Bright mode)
140W (Typ., Standard mode)
Voltage range 100-240VAC±10%, 50/60Hz±1Hz
Weight 24kg / 53lbs
Operating environment 5-35°C (41-95°F)
20-80% relative humidity
Other features Intel OPS slot x 1
Built-in stereo speakers (10W+10W)
Digital Gradation Circuit
Colour Space Control Circuit
1* The numbers are design figures only, and do not include the space between the display. When using BR-LM1KK, an addition gap of 1mm is required. B-to-B: Bezel to Bezel, A-to-A: Active to Active.

Specifications: LM55P1-W

Model LM55P1
Dimensions (W x H x D) 1215.5 x 686.3 x 128mm (47.9 x 27 x 5")
Display device TFT LCD (SPVA)
Screen surface treatment Anti-glare (Haze 44%)
Mullion size (Total) B-to-B 5.7mm (Typ.) / A-to-A 5.9mm (Typ.)*1
Display resolution Full HD (1920 x 1080 Pixels)
Viewable image size 55" (H: 1209.6mm/V: 680.4mm)
Back light technology LED (Direct)
Viewing angle(H/V) 178 Degree (CR>10)
Display orientation Landscape / Portrait
Brightness 700cd/m2 (Typ., High Bright mode)
500cd/m2 (Typ., Standard mode)
Contrast ratio 3,500:1 (Typ.)
Display colours 16.7 million
Input connectors Video DVI-D (with HDCP) x 1, HDMI x 1, DisplayPort (1.1a) x 1, D-sub15 x 1, Composite (BNC Y: shared with component video) x 1, Component(YPbPr) <BNC> x 1
Audio PC-audio (mini-pin) x 1, RCA-audio x 1
Control RS-232C x 1, ø3.5mm stereo mini jack x 1, LAN control (RJ-45) x 1
Output connectors Video DVI-D (with HDCP)
Audio RCA pin-jack x 1, External speaker jack x 1
Control RS-232C x 1, ø3.5mm stereo mini jack x 1
Signal frequency Analog H: 15.625/15.734/31.5-91.1KHz, V: 50/58-85Hz, Pixel clock: 13.5-165MHz
Digital H: 31.5-91.1KHz, V: 58-85Hz, Pixel clock: 25-165MHz
Power consumption 210W (Typ., High Bright mode)
180W (Typ., Standard mode)
Voltage range 100-240VAC±10%, 50/60Hz±1Hz
Weight 24kg / 53lbs
Operating environment 5-35°C (41-95°F)
20-80% relative humidity
Other features Intel OPS slot x 1
Built-in stereo speakers (10W+10W)
Digital Gradation Circuit
Colour Space Control Circuit

*1 The numbers are design figures only, and do not include the space between the display. When using BR-LM1KK, an addition gap of 1mm is required. B-to-B: Bezel to Bezel, A-to-A: Active to Active.